Posterior Solution

A smile for everyone. Posterior implant solutions.

Immediate placement in challenging post extraction sockets

Immediate implant placement has gained attention since its offers the advantages of reducing surgical intervention and treatment compared to conventional placement.(1)
Post extraction areas with immediate implant placement in a multi-rooted molar involves anatomical challenges that may compromise primary stability or cause damage of neighboring structures.(2,3)
The Neodent® Grand Morse® Helix® implant Ø6.0 mm was developed to efficiently treat post extraction sockets and satisfy patient’s high expectations.
To reach the market needs, was expanded the Posterior Solution with more options for post-extraction sockets in molar regions. This is the reason why Neodent® Grand Morse® Helix® Ø7.0mm implant was developed as well.

IMMEDIATE IMPLANT PLACEMENT WITH OPTIMIZED WIDE IMPLANT DESIGN

DELIVER NATURAL-LOOKING ESTHETICS THANKS TO AN OPTIMIZED WIDE EMERGENCE PROFILE DESIGN

Designed to achieve high primary stability in wide post extraction sockets

Grand Morse™ Helix™ – The Unbeatable Versatility

A wide customizable healing abutment was designed to maintain the molar emergence profile

Consistent emergence profile for excellent esthetic outcomes

IMMEDIATE IMPLANT PLACEMENT IN POST EXTRACTION SOCKETS WORKFLOW

1. Molar extraction site
 

2. Multi-rooted extraction socket
 

3. Immediate implant placement with
Helix GM™ 6.0 or 7.0mm

4. Customized natural-looking emergence profile using the wide customizable healing abutment

5. Wide Titanium Base abutment with consistent emergence profile
 

6. Digital or conventional

 


NEODENT® POSTERIOR SOLUTION OVERVIEW
SURGICAL

  • Same Grand Morse™ Connection
  • Same Grand Morse™ Surgical Kit and Instrumentals
  • Same Grand Morse™ Prosthetic Kit and Drivers

Implants

8 mm

10 mm

11.5 mm

13 mm

Ø6.0mm / Ø7.0mm

Ø6.0

Ø7.0

Customizable Healing Abutments

GH 1.5mm 2.5mm 3.5mm 4.5mm 5.5mm 6.5mm
  Ø5.5 and Ø7.0

Neo Manual Screwdriver

PROSTHETIC

GM Titanium Base

  GH 0.8mm 1.5mm 2.5mm 3.5mm 4.5mm
4mm Ø5.5
6mm

Use the Screwdriver Torque Connection - Torque Wrench

Final Restorations

Conventional

GM Titanium Base
Burn-out Coping
Ø5.5
4mm / 6mm

Digital

GM Hybrid
Repositionable Analog

Ø5.0/6.0

Downloads

Global Catalogue

Brochures

References

• Large retrospective clinical study: 2,244 implants placed in more than 400 patients.(1)
• Long-term high survival rate: 99.7% after up to 5 years. (1)
• No early loss of implants was found in this study.(1)
• High predictability in full arch restorations (4 to 6 or more in the maxilla and 4 or 5 in the mandible) even with tilted implants.(1)

1. Sartori IAM, Latenek RT, Budel LA, Thomé G, Bernardes SR, Tiossi R. Retrospective analysis of 2,244 nimplants and the importance of follow-up in implantology. Journal of Research in Dentistry. 2014 Nov- Dez;2(6):555-564.
2. Martin C, Thomé G, Melo AC, Fontão FN. Peri-implant bone response following immediate implants placed in the esthetic zone and with immediate provisionalization-a case series study. Oral Maxillofac Surg. 2015 Jun;19(2):157-63.
3. Barros RR, Novaes AB Jr, Muglia VA, Lezzi G, Piattelli A. Influence of interimplant distances and placement depth on peri-implant bone remodeling of adjacent and immediately loaded Morse cone connection implants: a histomorphometric study in dogs. Clin Oral Implants Res. 2010;21(4):371-8.
4. Castro DS, Araujo MA, Benfatti CA, Araujo Cdos R, Piattelli A, Perrotti V, et al. Comparative histological and histomorphometrical evaluation of marginal bone resorption around external hexagon and Morse cone implants: an experimental study in dogs. Implant Dent. 2014;23(3):270-6.
5. Novaes AB Jr, Barros RR, Muglia VA, Borges GJ. Influence of interimplant distances and placement depth on papilla formation and crestal resorption: a clinical and radiographic study in dogs. J Oral Implantol. 2009;35(1):18-27.
6. Siqueira RAC. Avaliação do índice de sucesso e comportamento dos tecidos periimplantares de implantes cone morse equicrestais ou subcrestais em arcos inferiores. [master’s dissertation on internet]. [Curitiba(Brazil)]: ILAPEO; 2013. [cited 28 out 2015] 126p. Available from: http://www.ilapeo.com.br/ Monografias_e_Dissertacoes/Dissertacoes_turma2011/Rafael_Amorin_Cavalcanti_de_Siqueira.pdf
7. Sotto-Maior BS, Lima Cde A, Senna PM, Camargos Gde V, Del Bel Cury AA. Biomechanical evaluation of subcrestal dental implants with different bone anchorages. Braz Oral Res. 2014;28.
8. Coppedê AR, Bersani E, Chiarello de Mattos MG, Rodrigues RCS, Sartori IAM, Ribeiro RF. Fracture  resistance of the implant-abutment connection in implants with internal hex and internal conical connections under oblique compressive loading: an in vitro study. Int J Prosthodont. 2009 May-Jun;22(3):283-6.
9. Bernardes SR, da Gloria Chiarello de Mattos M, Hobkirk J, Ribeiro RF. Loss of preload in screwed implant joints as a function of time and tightening/untightening sequences. Int J Oral Maxillofac Implants. 2014 Jan-Feb;29(1):89-96.
10. Jorge JR, Barao VA, Delben JA, Assuncao WG. The role of implant/abutment system on torque maintenance of retention screws and vertical misfit of implant-supported crowns before and after mechanical cycling. Int J Oral Maxillofac Implants. 2013 Mar-Apr;28(2):415-22.
11. dos Anjos CM, Harari ND, Reis RSA, Vidigal Junior GM. Análise in vitro da infiltração bacteriana na interface de pilares protéticos e implantes cone-morse / In vitro analysis of bacterial leakage at the interface between Morse taper implant platform and prosthetic abutments. ImplantNews. 2011 8(2):239- 243.
12. Sartoretto SC, Alves AT, Resende RF, Calasans-Maia J, Granjeiro JM, Calasans-Maia MD. Early osseointegration driven by the surface chemistry and wettability of dental implants. J Appl Oral Sci. 2015. May-Jun;23(3):279-87.
13. da Silveira BM. Análises tomográfica, microtomográfica e histológica entre enxertos em bloco autógeno e xenógeno nas reconstruções ósseas de maxila. [master’s dissertation on internet].[Curitiba(Brazil)]: ILAPEO; 2013. [cited 15 jun 2014] 133p. Available from: http://www.ilapeo.com.br/biblioteca-detalhe/ tomographic-microtomographic-and-histological-analysis-between-grafts-in-autogenous-andxenogeneic-- C162410.html
14. Mendonça G, Mendonça BD, Oliveira SL, Araujo AC. Efeitos da diferenciação de células-tronco mesenquimais humanas sobre superfícies de implantes hidrofílicas. ImplantNews. 2013 Nov-Dez 10(6a):111-116.